0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc

SC Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
     
    Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
    • Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
    • Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
    • Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
    • Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers
    • Buy cheap 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc from wholesalers

    0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc

    Ask Lasest Price
    Brand Name : MTL
    Model Number : MTL5532
    Certification : CE
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : on request
    • Product Details
    • Company Profile

    0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc

    MTL5532 PULSE ISOLATOR

    The MTLx532 isolates pulses from a switch, proximity detector, current pulse transmitter or voltage pulse transmitter located in a hazardous area. It is ideal for applications involving high pulse rates and fast response times, by repeating the pulses into the safe area. An analogue output proportional to frequency is also provided, together with a relay output, which may be configured to act as an alarm. Configuration is carried out with a personal computer.


    SPECIFICATION

    Number of channels

    One, fully floating

    Sensor type

    Switch or proximity detector (NAMUR/BS EN 60947–5–6:2001) 2– or 3–wire voltage or pulse transmitter

    Location of switch

    Zone 0, IIC, T6 hazardous area

    Div. 1, Group A, hazardous location

    Location of proximity detector or transmitter

    Zone 0, IIC, T4–T6 if suitably certified

    Div.1, Group A, hazardous location

    Input

    Switch input:

    Output ON if switch is closed

    Proximity detector input:

    Excitation: 7.0 to 9.0V dc from 1kΩ nominal

    Output ON if input > 2.1mA* (< 2kΩ)

    Output OFF if input < 1.2mA* (> 10kΩ)

    Switching hysteresis: 0.2mA (650Ω) nominal

    *NAMUR and BS EN 60947–5–6:2001standards

    Current pulse input:

    Transmitter supply: 16.5V dc at 20mA

    Short circuit current: 24mA

    Output: Iin > 9.0mA = ON, Iin < 7.0mA = OFF

    Switching hysteresis: 0.5mA

    Voltage pulse input

    Input impedance: > 10kΩ

    Switching point voltage (Vsp): 3, 6, or 12V nominal

    (User selectable by switches on the side of the module)

    Output: V in > Vsp = ON, Vin < Vsp = OFF

    Switching hysteresis: 100mV + (0.1 x Vsp) typical

    Safe-area pulse output

    Maximum delay: 10µs

    Maximum off–state voltage: 35V

    Maximum off–state leakage current: 10µA

    Maximum on–state resistance: 25Ω

    Maximum on–state current: 50mA

    Output OFF if supply fails

    Note: LFD signal is Zener-diode protected against inductive loads

    Safe-area current output

    Input capture delay: 2 signal periods (5ms min.)

    Signal range: 4 to 20mA

    Under/over range: 0 to 22mA

    Load resistance: 0 to 450Ω @20mA

    Output resistance: >1MΩ

    Ripple: < 50µA peak-to-peak

    Accuracy: better than 20µA at 20°C

    Temperature drift: < 1µA/°C

    Risetime (10% - 90%, after step change): 60 ms

    Alarm output

    Relay ON in alarm, 0.5A @ 35Vdc max.

    Pulse width

    High: 10µs min

    Low: 10µs min

    Frequency range

    0 – 50kHz - pulse output mode

    0 – 10KHz - for analogue output

    LED indicators

    Green: power indication

    Yellow: on when output circuit is on

    Red: flashing when line fault or error

    Power requirement

    65mA at 24V dc

    70mA at 20V dc

    55mA at 35V dc

    Power dissipation within unit

    1.35W maximum at 24V

    1.75W maximum at 35V

    Safety description (Um = 253V rms or dc)

    Terminals 2 to 1 and 6 to 1

    U =10.5V I =14mA P =37mW

    o o o

    Terminals 4 to 3 and 1

    Uo =28V Io =93mA Po =651mW

    Terminals 3 to 1

    Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW; can be

    connected without further certification into any IS loop with an open- circuit voltage <28V

    Terminals 5 to 4 and 1

    Vmax ≤ 28V, Imax ≤ 94mA, Pmax ≤ 0.66W

    Configurator

    A personal computer running MTL PCS45 software with a PCL45USB serial interface


    Related Part Number:


    HCU16

    MTL5521

    MTL4546Y

    MTL7761PAC

    HCU3700

    MTL5522

    MTL4549Y

    MTL7765AC

    HM64RIB20-1.0

    MTL5531

    MTL4573

    MTL7787+

    HM64RIB20-1.5

    MTL5532

    MTL4575

    MTL7787P+

    HMM64

    MTL5541

    MTL4646Y

    MTLCPS16

    HMRIB16-1.0

    MTL5541S

    MTL4850

    NJ5-18GK-N

    HMS64

    MTL5544

    MTL4851

    SD150X

    HTP-SC32

    MTL5544D

    MTL4852

    SD32

    MTL4044D

    MTL5546

    MTL5018

    SD32X

    MTL4511

    MTL5546Y

    MTL5032

    SDRTD

    MTL4516

    MTL5561

    MTL5042

    SLP32D

    MTL4516C

    MTL5573

    MTL5044

    TP48-3-I-NDI

    MTL4521

    MTL5575

    MTL5049

    TP48-3-N-NDI

    MTL4541

    MTL5582B

    MTL5511

    TP48-4-I-NDI

    PCL45USB

    MTL7728+

    MTL5514D

    TP48-4-N-NDI

    MTL4544

    MTL7756AC

    MTL5516

    TP48-N-NDI

    MTL4544D

    MTL7760AC

    MTL5516C

    ZB24571


    0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc

    Quality 0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SC Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)